General Purpose


  • Product Matrix
  • Technical Data Sheets

Water Soluble Corrosion Inhibitors

 

Product
Chemistry
Film Type
Corrosion Protection*
Amine Borate
Low tack
Up to 60 days
Amine Carboxylate
dry to touch
Up to 60 days
Borate/Carboxylate Blend
dry to touch
Up to 21 days
Nitrite
dry to touch
Up to 60 days
Amine Borate Blend
Low tack
Up to 40 days

 

* The length of corrosion protection depends on a number of variables such as product concentration, part cleanliness, part configuration, packaging conditions and storage conditions. Please contact our technical department for assistance in determining which product would best suit your needs.

 

Solvent/Oil Based Corrosion Inhibitors

 

Product
Organic Carrier
Water Displacing
Film Thickness
Film Type
Flash Point
Humidity Cabinet¹
Days to Failure
Salt Spray²
Hrs to Failure
Solvent
NO
1.75 mils
dry to touch
100°F
200
1000
Solvent
YES
0.02 mils
dry to touch
125°F
30
N/A
Solvent
YES
0.04 mils
dry to touch
104°F
40
24
Solvent
YES
0.06 mils
dry to touch
142°F
60
N/A
Oil
YES
1.0 mils
oily
>300°F
40
N/A
Oil/Solvent Blend
YES
0.08 mils
oily
142°F
50
N/A

 

¹ ASTM D-1748 using polished cold rolled panels

² ASTM B-117 using polished cold rolled panels

The Lily Difference...

Our data/analytical approach makes us unique to the market, because we are more than just a chemical company. We want to play more of a meaningful role in your business to meet and exceed your chemical process needs. Click on our Lily Difference and look at our 6th Man Philosophy.